Veris Extended Range V400D Spec Sheet User Manual

Browse online or download User Manual for Equipment Veris Extended Range V400D Spec Sheet. Veris Extended Range V400D Spec Sheet User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 4
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Differential Pressure Flow Sensors
Verabar
®
Model Specs V400D
Pipe Connection Flanged
Sensor Code 20
Sensor Diameter 2” (51mm)
Accuracy
±1% of flow rate;
±0.5% if calibrated
ANSI Class* 150#, 300#, 600#
Drive Rods 2
Pipe Size
12”-60”
(300mm-1524mm)
Instrument
Connection
1/2” NPT
Components Weld coupling, weld neck
Furnished flange, gaskets,
studs & nuts
Flange Size 3”
The Most Accurate and Reliable Technology
for Measuring Gas, Liquid and Steam…
The extended range Verabar® is engineered
for liquid, steam and high velocity gas
flow measurement in larger pipe
sizes, up to 60” (1524mm). With
its solid, one-piece construction
and bullet shape, the Verabar
makes flow measurement
leak proof and precise.
The unique
sensor shape
reduces drag
and flow induced
vibration. The location
of the low-pressure ports
eliminates the potential for clogging
and improves signal stability.
Extended Range
Hot Tap Models
V400D Double Rod
Flanged Components
V400D Synchro-Drive
(Standard)
Instrument
head (SS)
Drive
nut
Drive
chain
Protective
chain shroud
Anti-seize
orbital bearing
Packing gland
(SS)
Access nipple
(SS)
Flanged
access valve
(CS) (SS-opt)
Weld coupling
(CS) (SS-opt)
Weld neck
flange
(CS) (SS-opt)
Spiral-
wound
gasket (2)
Sensor
(316SS)
Optional:
Monel 400
Hastelloy C-276
Inconel 800H
316HSS
Drive rod (SS)
Synchro-Drive Description
Synchro-Drive is standard on all – 20 sensors. Two drive
rods are coupled together by a protected chain drive
system. Turning either drive nut simultaneously rotates
both rods.
Synchro-Drive Benefits
• 95% faster and easier insertion and retraction
• Equal load distribution over both rods maintains sensor
alignment and eliminates binding
Temperature
Pressure
Limits
(ANSI Class)*
150#
275 psig @ 100°F
(19 Bars @ 38°C)
80 psig @ 800°F
(5.5 Bars @ 426°C)
300#
720 psig @ 100°F
(49.6 Bars @ 38°C)
410 psig @ 800°F
(28.3 Bars @ 426°C)
600#
1440 psig @ 100°F
(99.3 Bars @ 38°C)
825 psig @ 800°F
(56.9 Bars @ 426°C)
* DIS and JIS flanges available. Consult factory.
Page view 0
1 2 3 4

Summary of Contents

Page 1 - Hot Tap Models

Differential Pressure Flow SensorsVerabar®Model Specs V400DPipe Connection FlangedSensor Code 20Sensor Diameter 2” (51mm)Accuracy±1% of flow rate; ±0.

Page 2 - Ordering Information

Ordering InformationModel Extended Range Hot Tap • Screw DriveV400D Double Rod, Insert/RetractPipe Size and Schedule or Exact ID and Wall ThicknessCod

Page 4

6315 Monarch Park Place •Niwot, CO 80503 USA •Phone: 303-652-8550 •Fax: 303-652-8552E-Mail: [email protected] •Website: www.veris-inc.comTrue

Comments to this Manuals

No comments